| Load Group | Circuit / Rough-In | Count | Notes |
|---|---|---|---|
| Wall duplex receptacles | 120V branch circuit | 27 | Standard wall duplex outlets shown in the main wall-load DWFx. Circuit grouping follows the panel schedules. |
| Floor duplex receptacles | 120V branch circuit | 5 | DWFx family is Outlet Floor-Duplex. Coordinate final box/device type with floor finish and cover requirements. |
| Waterproof receptacles | 120V weatherproof/GFCI where required | 14 | DWFx family is Outlet-WP / Water Proof. Use in-use covers and GFCI protection where code requires. |
| Countertop GFI receptacles | 120V GFCI branch circuit | 14 | DWFx family is Outlet-GFI / Countertop. Provide kitchen, bath, wet-location, and countertop protection as required. |
| Island GFI receptacles | 120V GFCI branch circuit | 4 | DWFx family is Outlet-GFI / Island. Coordinate final island/peninsula receptacle placement with cabinet shop and code. |
| Range outlets | Equipment circuit, verify voltage/amps | 3 | DWFx family is Outlet-Range / Single / Range. Verify each appliance cut sheet before breaker and conductor sizing. |
| Microwave outlet | Dedicated or appliance branch circuit | 1 | DWFx family is Outlet-Range / Micro Wave. Verify whether dedicated circuit is required by equipment and code. |
| Stack washer/dryer outlet | Laundry equipment circuit | 1 | DWFx family is Outlet-Range / Stack. Verify actual washer/dryer voltage and amp requirements before rough-in. |
| 240V fusible 30A disconnects | 240V equipment disconnect | 4 | DWFx object type is Disconnect Switches / 240V - Fusible 30A. Coordinate final fuse size with served equipment. |
| 240V fusible 40A disconnect | 240V equipment disconnect | 1 | DWFx object type is Disconnect Switches / 240V - Fusible 40A. Verify equipment nameplate before installation. |
| LAN1 wall controls | Low-voltage/control rough-in | 6 | DWFx family is Switch-Three Way / LAN1. Treat as control/keypad rough-in unless electrical designer revises. |
| LAN4 PoE touch screens | Cat5e/PoE rough-in | 5 | DWFx type mark is 8" Android PoE Touch Screen. Pull Cat5e to the assigned low-voltage/control location. |
| LAN5 wall controls | Low-voltage/control rough-in | 3 | DWFx family is Switch-Three Way / LAN 5. Coordinate control function with lighting/control schedule. |
| CATV + 120V combo outlets | Low-voltage + 120V combo rough-in | 3 | DWFx family is Outlet-Communications / CATV; model notes Legrand 9" and 120V duplex. Coordinate low-voltage and power separation. |
| Load Group | Voltage | Control | Notes |
|---|---|---|---|
| Mechanical utility light | 120V | Local motion or shared relay | Loop on the Panel 3 utility 20A lighting circuit. |
| Garage mechanical utility light | 120V | Local motion or shared relay | Loop on the Panel 3 utility 20A lighting circuit. |
| Pantry/storage utility light | 120V | Local motion or shared relay | Loop on the Panel 3 utility 20A lighting circuit. |
| Three additional utility lights | 120V | Local motion | Include all three utility/motion fixtures on shared 1-120 feed; no separate Shelly needed if only motion-control is desired. |
| ADU 120V utility light | 120V | Local motion or shared relay | Include on 1-120 where code/load allows unless a separate controlled feed is intentionally shown. |
| Independently switched 120V loads | 120V | Shelly relay channel/module | Same branch circuit is acceptable; independent control requires separate relay output/channel. |
| Item | Spec / Basis | Qty | Use / Notes |
|---|---|---|---|
| Interior LED tape | 24V, 3000K, 95+ CRI, 3.1 W/LF, indoor/damp | 10 x 100 ft spools | Install at all interior and ADU ceiling tape locations shown on the plan. |
| Exterior LED tape | 24V, 3000K, wet-location/IP-rated, 3.1 W/LF basis | 7 x 100 ft spools | Install at all exterior ceiling tape locations shown on the plan. |
| Interior aluminum channel | 8 ft aluminum profile with frosted lens, end caps, clips | 120 sticks | Use at all interior cove/tray/tape locations. |
| Exterior aluminum channel | 8 ft exterior/wet-rated aluminum profile with lens, end caps, clips | 78 sticks | Seal wire exits; mechanically fasten; do not rely on adhesive only. |
| 24V LED drivers | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A power supply | 12 DIN supplies | Purchasable power supply. This is not one driver per Shelly. Use 8 DIN supplies for UDB Upper lighting and 4 DIN supplies for LDB Lower lighting; each supply feeds multiple individually fused Shelly/tape outputs as scheduled below. |
| UDB assembly - Upper lighting 24V controls | 8 x Mean Well SDR-480-24 DIN power supplies + 2 x nVent Hoffman A42N3013 driver enclosures + 1 x nVent Hoffman A42N3613 low-voltage enclosure + Phoenix Contact 3036505 fused DIN terminals + Shelly Pro RGBWW PM modules | 1 assembly | Buildable upper-ceiling assembly. Feeds 17 current upper DWFx 24V zones. Label outputs UDB / PS-# / F-# / SH-# / U-#. |
| LDB assembly - Lower lighting 24V controls | 4 x Mean Well SDR-480-24 DIN power supplies + 1 x nVent Hoffman A42N3013 driver enclosure + 1 x Hoffman A24N206LP low-voltage enclosure + Phoenix Contact 3036505 fused DIN terminals + Shelly Pro RGBWW PM modules | 1 assembly | Buildable lower-ceiling assembly. Feeds 7 current lower DWFx 24V zones. Label outputs LDB / PS-# / F-# / SH-# / L-#. |
| 24V fused distribution terminals | Phoenix Contact ST 4-FSI/C-LED 24 fuse terminal block, item 3036505, on NS35 DIN rail | 24 minimum + spares | Use one fused 24V positive output per Shelly/tape zone. Size the blade fuse to the actual tape load and wire gauge. Do not land all 24V loads on an unfused common bus. |
| Shelly LED controllers | Shelly Pro RGBWW PM, white-channel mode | 24 max | Carry one module per visible 24V control label in the current upper/lower ceiling DWFx files. Module count may be reduced only if multiple white channels are grouped on one Shelly and channel/module load ratings remain compliant. |
| Driver-bank enclosures | nVent Hoffman Type 1 steel wall-mount enclosures: A42N3013 for driver cabinets, A42N3613 for upper 24V controls, A24N206LP for lower 24V controls and shades | 6 total | Use UDB-A, UDB-B, UDB-C, LDB-A, LDB-B, and BC-1. Keep 120V driver cabinets separate from 24V fused/Shelly control cabinets. |
| DIN rail | Phoenix Contact NS 35/7.5 perforated DIN rail, 35 mm x 7.5 mm | As required | Mount fuse terminals and control terminals inside each Hoffman control/fuse enclosure. |
| 120V branch circuits | Dedicated 120V lighting circuits to UDB and LDB assemblies | 6 x 20A | Use two SDR-480-24 supplies per 20A feed: four feeds to UDB-A/UDB-B and two feeds to LDB-A. Run each feed as a dedicated 20A lighting/control branch with #12 copper conductors and equipment ground in raceway/cable method accepted for the installation. |
| 120V utility / motion lights | Shared 120V lighting circuit for utility fixtures | 1 circuit | Combine mechanical, garage mechanical, pantry/storage, ADU 120V, and three utility/motion fixtures on one existing 120V lighting circuit where code/load allows. |
| Cat5e control cable | CMR/CL2 rated Cat5e, home-run topology | 2 x 1000 ft boxes | For keypad/control/low-voltage signal runs only. Do not use Cat5e for LED tape power. |
| LED power cable | 16/2 stranded low-voltage cable, CL2/CL3 as required | 2 x 1000 ft boxes | Typical 24V tape home runs from controller to tape. |
| Long-run LED power cable | 14/2 stranded low-voltage cable, CL2/CL3 as required | 1 x 500 ft box | Use for longer 24V home runs and power injection where voltage drop requires. |
| Circuit | Area Served | Shelly Zones | 24V Bank Capacity | Breaker |
|---|---|---|---|---|
| UDB / Upper lighting | Build UDB from 8 x Mean Well SDR-480-24 DIN power supplies, 2 x Hoffman A42N3013 driver enclosures, 1 x Hoffman A42N3613 low-voltage enclosure, Phoenix Contact 3036505 fused terminals, and Shelly Pro RGBWW PM modules. | 17 | 3,840W @ 24V | 4 x 20A, 120V |
| LDB / Lower lighting | Build LDB from 4 x Mean Well SDR-480-24 DIN power supplies, 1 x Hoffman A42N3013 driver enclosure, 1 x Hoffman A24N206LP low-voltage enclosure, Phoenix Contact 3036505 fused terminals, and Shelly Pro RGBWW PM modules. | 7 | 1,920W @ 24V | 2 x 20A, 120V |
| Plan Label | Meaning | Required Connection |
|---|---|---|
| 1-24 2-24 3-24 | Separate 24V tape-light control zones | Mean Well SDR-480-24 DIN 24V power supply to Phoenix Contact 3036505 fused terminal, then Shelly Pro RGBWW PM, then tape zone. |
| 120V | Line-voltage feed to driver location | 120V circuit feeds accessible 24V DIN power supplies only. |
| 1-120 | Shared 120V utility/motion lighting circuit | Use one 120V lighting feed for the miscellaneous utility fixtures; local motion sensors are acceptable. |
| 3-120 | Single remaining 120V label in latest DWFx | Use only where a separate 120V controlled feed is intentionally required; otherwise use the Panel 3 utility 20A lighting circuit. |
| 4-120 5-120 | Not present in latest DWFx | Do not carry these as separate circuits. Latest DWFx text shows 1-120 and 3-120 only. |
| Shelly | Shelly Pro RGBWW PM smart PWM controller | Install downstream of the Phoenix Contact 3036505 fused 24V output and upstream of tape light. |
| 120V Shelly | Only for separately controlled 120V loads | Loads may share the same 120V branch circuit, but independent app/control switching requires separate Shelly relay channels/modules. |
| Cat5e | Control/keypad cable only | Home run from switch/keypad/control points to low-voltage cabinet. |
| Assembly | Driver No. | Driver Product | Fused Output | Fuse Product | Shelly No. | Shelly Product | Tape Termination | Area / Plan Callout |
|---|---|---|---|---|---|---|---|---|
| UDB | PS-1 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-01 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-01 | Shelly Pro RGBWW PM | U-01 / 1-24 | Upper ceiling left-side area |
| UDB | PS-1 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-02 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-02 | Shelly Pro RGBWW PM | U-02 / 2-24 | Upper ceiling left-side area |
| UDB | PS-2 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-03 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-03 | Shelly Pro RGBWW PM | U-03 / 1-24 | Upper ceiling lower-left area |
| UDB | PS-2 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-04 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-04 | Shelly Pro RGBWW PM | U-04 / 1-24 | Upper ceiling left wing area |
| UDB | PS-3 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-05 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-05 | Shelly Pro RGBWW PM | U-05 / 1-24 | Upper ceiling left wing area |
| UDB | PS-3 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-06 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-06 | Shelly Pro RGBWW PM | U-06 / 1-24 | Upper ceiling center-left area |
| UDB | PS-4 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-07 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-07 | Shelly Pro RGBWW PM | U-07 / 2-24 | Upper ceiling center-left area |
| UDB | PS-4 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-08 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-08 | Shelly Pro RGBWW PM | U-08 / 1-24 | Upper ceiling upper central area |
| UDB | PS-5 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-09 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-09 | Shelly Pro RGBWW PM | U-09 / 2-24 | Upper ceiling upper central area |
| UDB | PS-5 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-10 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-10 | Shelly Pro RGBWW PM | U-10 / 1-24 | Upper ceiling kitchen/service bar area |
| UDB | PS-6 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-11 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-11 | Shelly Pro RGBWW PM | U-11 / 1-24 | Upper ceiling kitchen/service bar area |
| UDB | PS-6 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-12 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-12 | Shelly Pro RGBWW PM | U-12 / 1-24 | Upper ceiling right-side exterior/patio area |
| UDB | PS-7 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-13 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-13 | Shelly Pro RGBWW PM | U-13 / 1-24 | Upper ceiling main room rectangle |
| UDB | PS-7 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-14 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-14 | Shelly Pro RGBWW PM | U-14 / 2-24 | Upper ceiling main room rectangle |
| UDB | PS-8 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-15 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-15 | Shelly Pro RGBWW PM | U-15 / 1-24 | Upper ceiling bedroom/right-side area |
| UDB | PS-8 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-16 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-16 | Shelly Pro RGBWW PM | U-16 / 1-24 | Upper ceiling bedroom/right-side area |
| UDB | PS-8 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-17 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-17 | Shelly Pro RGBWW PM | U-17 / 1-24 | Upper ceiling bath/service area |
| LDB | PS-1 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-01 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-01 | Shelly Pro RGBWW PM | L-01 / 1-24 | Lower ceiling living/mechanical utility light area |
| LDB | PS-1 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-02 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-02 | Shelly Pro RGBWW PM | L-02 / 2-24 | Lower ceiling main/ADU rectangle area |
| LDB | PS-2 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-03 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-03 | Shelly Pro RGBWW PM | L-03 / 1-24 | Lower ceiling main/ADU rectangle area |
| LDB | PS-2 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-04 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-04 | Shelly Pro RGBWW PM | L-04 / 1-24 | Lower ceiling rear patio / exterior area |
| LDB | PS-3 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-05 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-05 | Shelly Pro RGBWW PM | L-05 / 2-24 | Lower ceiling bedroom/right-side area |
| LDB | PS-3 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-06 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-06 | Shelly Pro RGBWW PM | L-06 / 3-24 | Lower ceiling bedroom/right-side area |
| LDB | PS-4 | Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-07 | Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-07 | Shelly Pro RGBWW PM | L-07 / 1-24 | Lower ceiling right-side service/bath area |
| Item | System | Qty | Use / Notes |
|---|---|---|---|
| Duplex receptacles | 120V branch circuit | 11 | Standard wall duplex outlets shown in the upper wall-load DWFx. Circuit grouping follows the panel schedules. |
| GFI receptacles | 120V GFCI branch circuit | 3 | GFI outlets shown in DWFx, including island/counter locations. Provide GFCI protection as required by code. |
| Weatherproof outlets | 120V exterior/wet-rated branch circuit | 5 | Includes 4 WP outlet objects plus 1 dryer WP outlet object. Use wet-location boxes/covers where required. |
| Hybrid water heater outlet | 240V equipment circuit | 1 | DWFx object is Outlet-Range / Water Heater Hybrid. Verify circuit size with equipment submittal. |
| Fusible disconnects | 240V equipment disconnect | 2 | DWFx object type is 240V fusible 30A. Coordinate final disconnect/fuse size with equipment served. |
| Wall control / switch devices | Low voltage / control | 9 | Includes 5 LAN1 control points and 4 Axion 8 in Android PoE touch screen objects. Coordinate PoE/data rough-in. |
| Garage door ceiling receptacles | 120V branch circuit | 4 | Provide one ceiling receptacle at each garage door opener location. Coordinate exact placement with opener rail/motor locations before rough-in. |
| Communications / CATV outlet | Low voltage | 1 | Low-voltage communication outlet. Do not mix with 120V conductors except in listed combo devices/boxes as allowed. |
| Item | Spec / Basis | Qty / Load | Use / Notes |
|---|---|---|---|
| Interior upper ceiling tape | 24V, 3000K, 95+ CRI, 3.1 W/LF, indoor/damp | 817.1 LF takeoff / 940 LF with 15% | Interior upper ceiling tape shown in the upper ceiling DWFx. Included in total tape package unless ordered separately. |
| Exterior upper ceiling tape | 24V, 3000K, wet-location/IP-rated, 3.1 W/LF basis | Use only where exterior/wet shown | Keep exterior tape and exterior channel separate from interior material. Do not install indoor tape/channel outside. |
| Upper ceiling load basis | 24V DC tape load | 2,533W at 3.1 W/LF | If the Revit 9 W/LF RGBW family is used, load becomes approx. 7,354W and the driver schedule must be redesigned. |
| Upper ceiling Shelly controls | Shelly Pro RGBWW PM or approved equivalent | Per visible 24V label | One module/channel per control label unless grouping is specifically approved and documented. |
| Upper 24V driver assignment | Mean Well SDR-480-24 DIN power supply through Phoenix Contact 3036505 fused terminal output | UDB | Assign upper ceiling zones U-01 through U-17 to scheduled UDB outputs. Do not move zones between UDB and LDB without revised load, fuse, and voltage-drop schedules. |
| 120V feed | Four dedicated 20A 120V lighting/control feeds to UDB assembly | UDB-A / UDB-B | Use two Mean Well SDR-480-24 DIN power supplies per 20A feed. Tape zones are 24V downstream of the supplies, Phoenix Contact fuse terminals, and Shelly modules. |
| Cat5e control cable | CMR/CL2 rated Cat5e, home-run topology | As required | For keypad/control/low-voltage signal only. Do not use Cat5e for LED tape power. |
| LED power cable | 16/2 stranded CL2/CL3, 14/2 where voltage drop requires | As required | Home-run 24V tape power from the assigned Shelly/controller output to the tape zone. |
| Item | System | Qty | Use / Notes |
|---|---|---|---|
| Duplex receptacles | 120V branch circuit | 11 | Standard wall duplex outlets shown in the lower wall-load DWFx. Circuit grouping follows the panel schedules. |
| GFI receptacles | 120V GFCI branch circuit | 3 | Countertop/wet-location GFI outlets shown in DWFx. Provide GFCI protection as required by code. |
| Communications / CATV outlet | Low voltage | 1 | Low-voltage communication outlet. Do not mix with 120V conductors except in listed combo devices/boxes as allowed. |
| Wall control / switch devices | Low voltage / control | 3 | DWFx object family is Switch-Three Way with Axion 8 in Android PoE touch screen metadata. Coordinate PoE/data rough-in. |
| Data / media panel | Low voltage / structured wiring | 1 | Leviton 28 in media center shown in DWFx. Provide power and low-voltage home runs as required. |
| Echo / Nest hub locations | Low voltage / 120V adapter as required | 2 | Coordinate mounting, power, and network requirements before rough-in. |
| Control discs / controllers | Low voltage / control | 5 | DWFx includes Honeywell-style controllers/meters/gauges. Coordinate exact controls scope before final wiring. |
| AV wall-load equipment | 120V + low voltage / speaker | 6 devices | Includes 2 Martin Logan wall speakers, 2 Martin Logan subwoofers, 1 Macintosh receiver, and 1 150 in screen. Coordinate power, speaker cable, conduit, and data. |
| Smart toilet power | 120V GFCI where required | 1 | Smart toilet object is shown in DWFx. Verify whether it needs a dedicated/receptacle feed and GFCI protection. |
| Item | Spec / Basis | Qty / Load | Use / Notes |
|---|---|---|---|
| Interior lower ceiling tape | 24V, 3000K, 95+ CRI, 3.1 W/LF, indoor/damp | Part of 356.2 LF takeoff / 410 LF with 15% | Interior lower ceiling and ADU tape locations shown on the plan. Use interior/damp tape and interior aluminum channel. |
| Exterior lower ceiling tape | 24V, 3000K, wet-location/IP-rated, 3.1 W/LF basis | Part of 356.2 LF takeoff / 410 LF with 15% | Exterior lower/rear patio tape locations shown on the plan. Use wet-rated tape, wet-rated channel, lens, caps, clips, sealed exits, and mechanical fastening. |
| Lower ceiling load basis | 24V DC tape load | 1,104W at 3.1 W/LF | If the Revit 9 W/LF RGBW family is used, load becomes approx. 3,206W and the driver schedule must be redesigned. |
| Lower ceiling Shelly controls | Shelly Pro RGBWW PM or approved equivalent | Per visible 24V label | One module/channel per control label unless grouping is specifically approved and documented. |
| Lower 24V driver assignment | Mean Well SDR-480-24 DIN power supply through Phoenix Contact 3036505 fused terminal output | LDB | Assign lower/ADU/exterior zones L-01 through L-07 to scheduled LDB outputs. Do not move zones between UDB and LDB without revised load, fuse, and voltage-drop schedules. |
| 120V feed | Two dedicated 20A 120V lighting/control feeds to LDB assembly | LDB-A | Use two Mean Well SDR-480-24 DIN power supplies per 20A feed. Tape zones are 24V downstream of the supplies, Phoenix Contact fuse terminals, and Shelly modules. |
| Cat5e control cable | CMR/CL2 rated Cat5e, home-run topology | As required | For keypad/control/low-voltage signal only. Do not use Cat5e for LED tape power. |
| LED power cable | 16/2 stranded CL2/CL3, 14/2 where voltage drop requires | As required | Home-run 24V tape power from the assigned Shelly/controller output to the tape zone. |
| Circuit | Mean Well Driver | Fused Output | Shelly Module | Termination |
|---|---|---|---|---|
| Upper ceiling / UDB / U-01 / 1-24 | UDB / PS-1 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-01 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-01 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at left-side upper area. |
| Upper ceiling / UDB / U-02 / 2-24 | UDB / PS-1 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-02 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-02 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout paired with U-01 at left-side upper area. |
| Upper ceiling / UDB / U-03 / 1-24 | UDB / PS-2 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-03 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-03 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at lower-left upper area. |
| Upper ceiling / UDB / U-04 / 1-24 | UDB / PS-2 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-04 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-04 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at left wing / interior tape area. |
| Upper ceiling / UDB / U-05 / 1-24 | UDB / PS-3 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-05 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-05 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at left wing / interior tape area. |
| Upper ceiling / UDB / U-06 / 1-24 | UDB / PS-3 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-06 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-06 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at center-left upper area. |
| Upper ceiling / UDB / U-07 / 2-24 | UDB / PS-4 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-07 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-07 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout paired with U-06 at center-left upper area. |
| Upper ceiling / UDB / U-08 / 1-24 | UDB / PS-4 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-08 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-08 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at upper central upper area. |
| Upper ceiling / UDB / U-09 / 2-24 | UDB / PS-5 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-09 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-09 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout paired with U-08 at upper central upper area. |
| Upper ceiling / UDB / U-10 / 1-24 | UDB / PS-5 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-10 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-10 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at upper upper exterior/interior run. |
| Upper ceiling / UDB / U-11 / 1-24 | UDB / PS-6 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-11 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-11 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at center upper run. |
| Upper ceiling / UDB / U-12 / 1-24 | UDB / PS-6 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-12 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-12 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at right/ADU-side upper area. |
| Upper ceiling / UDB / U-13 / 1-24 | UDB / PS-7 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-13 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-13 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at right/ADU-side upper area. |
| Upper ceiling / UDB / U-14 / 2-24 | UDB / PS-7 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-14 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-14 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout paired with U-13 at right/ADU-side upper area. |
| Upper ceiling / UDB / U-15 / 1-24 | UDB / PS-8 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-15 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-15 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at right-side upper exterior/interior run. |
| Upper ceiling / UDB / U-16 / 1-24 | UDB / PS-8 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-16 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-16 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at far-right upper run. |
| Upper ceiling / UDB / U-17 / 1-24 | UDB / PS-8 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-17 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-17 - Shelly Pro RGBWW PM | Current upper ceiling DWFx callout at lower-right upper run. |
| Lower ceiling / LDB / L-01 / 1-24 | LDB / PS-1 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-01 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-01 - Shelly Pro RGBWW PM | Current lower ceiling DWFx callout at upper-left lower-ceiling area. |
| Lower ceiling / LDB / L-02 / 2-24 | LDB / PS-1 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-02 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-02 - Shelly Pro RGBWW PM | Current lower ceiling DWFx callout paired with L-01 at upper-left lower-ceiling area. |
| Lower ceiling / LDB / L-03 / 1-24 | LDB / PS-2 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-03 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-03 - Shelly Pro RGBWW PM | Current lower ceiling DWFx callout at central lower-ceiling area. |
| Lower ceiling / LDB / L-04 / 1-24 | LDB / PS-2 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-04 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-04 - Shelly Pro RGBWW PM | Current lower ceiling DWFx callout at lower-left ADU/lower area. |
| Lower ceiling / LDB / L-05 / 2-24 | LDB / PS-3 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-05 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-05 - Shelly Pro RGBWW PM | Current lower ceiling DWFx callout paired with L-04 at lower-left ADU/lower area. |
| Lower ceiling / LDB / L-06 / 3-24 | LDB / PS-3 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-06 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-06 - Shelly Pro RGBWW PM | Current lower ceiling DWFx callout grouped with L-04 and L-05 at lower-left ADU/lower area. |
| Lower ceiling / LDB / L-07 / 1-24 | LDB / PS-4 - Mean Well SDR-480-24, DIN rail, 480W, 24VDC, 20A | F-07 - Phoenix Contact 3036505 ST 4-FSI/C-LED 24 fused terminal | SH-07 - Shelly Pro RGBWW PM | Current lower ceiling DWFx callout at right-side lower-ceiling area. |
| Main wall loads / 120V / GFCI 1-120 | 120V GFCI branch circuit, no Mean Well driver | No 24V fused output | No Shelly unless independent control is required | Current main wall-load DWFx GFCI label. |
| Main wall loads / 120V / GFCI 120-1 | 120V GFCI branch circuit, no Mean Well driver | No 24V fused output | No Shelly unless independent control is required | Current main wall-load DWFx GFCI label. |
| Main wall loads / 120V / GFCI 120-2 | 120V GFCI branch circuit, no Mean Well driver | No 24V fused output | No Shelly unless independent control is required | Current main wall-load DWFx GFCI label. |
| Main wall loads / 120V / GFCI-120-2 | 120V GFCI branch circuit, no Mean Well driver | No 24V fused output | No Shelly unless independent control is required | Current main wall-load DWFx GFCI label. |
| Main wall loads / 120V / GFCI 120-3 | 120V GFCI branch circuit, no Mean Well driver | No 24V fused output | No Shelly unless independent control is required | Current main wall-load DWFx GFCI label. |
| Item | Exact Product / Basis | Qty | Electrical / Control Notes |
|---|---|---|---|
| Shade motors | Somfy Sonesse RS485 family, 120VAC. Use Sonesse 506S2 RS485 / Sonesse 60 RS485 / Hi-Torque RS485 as sized per opening by shade vendor. | 11 motors | Each motor gets 120VAC power plus RS485/data control as required by Somfy SDN. Final motor model must match tube size, shade size, and torque. |
| RS485 network controller | Somfy animeo IP/RS485 control system or approved Somfy SDN IP/RS485 interface | 1 system | Network control path for Somfy RS485 motors. Coordinate Homey/LAN integration here, not through the 24V lighting driver bank. |
| Shade power circuit | Dedicated 120VAC shade motor branch circuit | 1 x 15A | Takeoff load is 4.89A / 586.8W total. Run as a dedicated 15A branch to BC-1 with #14 copper minimum or #12 copper where project wiring standard uses #12 for lighting/control. |
| Data/control cable | RS485/SDN bus cable per Somfy requirements; keep polarity and termination per Somfy wiring guide | As required | Home run or bus topology by Somfy requirements. Label every motor drop by opening name. |
| Shelly note | Shelly Pro Dual Cover/Shutter PM is only for non-RS485 bidirectional AC cover motors | Do not use with RS485 basis unless system is revised | If the shade vendor changes to standard AC up/down motors instead of Somfy RS485 motors, then use 6 x Shelly Pro Dual Cover/Shutter PM for 11 motors. Do not mix that assumption into the current RS485 Somfy basis. |
| Opening | Size | Motor Basis | Amps | Watts | Control | |
|---|---|---|---|---|---|---|
| Entry | 159 in x 268.5 in | Somfy Sonesse 100 RS485, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 8 in | Somfy RS485 bus to LAN/Homey |
| Entry 2 | 96 in x 268.5 in | Somfy Sonesse 100 RS485, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 8 in | Somfy RS485 bus to LAN/Homey |
| West Glass 1 | 268 in x 314.5 in | Somfy Sonesse 100 RS485 Hi-Torque, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 10 in | Somfy RS485 bus to LAN/Homey |
| West Glass Lower 1 | 120 in x 207 in | Somfy Sonesse 100 RS485, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 8 in | Somfy RS485 bus to LAN/Homey |
| West Glass Lower 2 | 120 in x 209.75 in | Somfy Sonesse 100 RS485, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 8 in | Somfy RS485 bus to LAN/Homey |
| West Glass Upper 1 | 144 in x 236.75 in | Somfy Sonesse 100 RS485, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 8 in | Somfy RS485 bus to LAN/Homey |
| West Glass Upper 2 | 120 in x 110.5 in | Somfy Sonesse 60 RS485, 60 mm tube, single roller OK | 0.35 | 42.0 | 6 in | Somfy RS485 bus to LAN/Homey |
| West Glass 2-1 | 120 in x 161.5 in | Somfy Sonesse 60 RS485, 60 mm tube, dual roller recommended | 0.35 | 42.0 | 6 in | Somfy RS485 bus to LAN/Homey |
| West Glass 2-2 | 120 in x 228.5 in | Somfy Sonesse 100 RS485, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 8 in | Somfy RS485 bus to LAN/Homey |
| Glass South | 91 in x 113.25 in | Somfy Sonesse 60 RS485, 60 mm tube, single roller OK | 0.35 | 42.0 | 6 in | Somfy RS485 bus to LAN/Homey |
| Glass East | 119 in x 234 in | Somfy Sonesse 100 RS485, 100 mm tube, dual roller recommended | 0.48 | 57.6 | 8 in | Somfy RS485 bus to LAN/Homey |
| Area Group | 120V Source Panel / Circuit Group | Power Supply Cabinet / Supplies | Low-Voltage Cabinet Devices | Field Terminations / Areas |
|---|---|---|---|---|
| Upper left / Panel 1 area | Panel 1 upper lighting/control circuits serving the left-side upper ceiling zones | LVP-1: Mean Well SDR-480-24 supplies PS-1, PS-2, and PS-3 | LVP-1: Phoenix fused outputs F-01 through F-05; Shelly Pro RGBWW PM modules SH-01 through SH-05 | U-01 through U-05: upper left-side, lower-left, and left-wing tape-light areas |
| Upper center / right / Panel 2 area | Panel 2 upper lighting/control circuits serving the center and right-side upper ceiling zones | LVP-2: Mean Well SDR-480-24 supplies PS-4 through PS-8 | LVP-2: Phoenix fused outputs F-06 through F-17; Shelly Pro RGBWW PM modules SH-06 through SH-17 | U-06 through U-17: center-left, upper central, kitchen/service bar, right-side exterior/patio, main room rectangle, bedroom/right-side, and bath/service areas |
| Lower/main / Panel 3 area | Panel 3 lower/main lighting/control circuits, including the shared utility/motion light branch where shown | LVP-3: Mean Well SDR-480-24 supplies PS-9 and PS-10 | LVP-3: Phoenix fused outputs F-18 through F-21; Shelly Pro RGBWW PM modules SH-18 through SH-21 | L-01 through L-04: lower living/mechanical utility, main/ADU rectangle, and rear patio/exterior tape-light areas |
| Lower/right / ADU / Panel 4 area | Panel 4 lower/right and ADU-side lighting/control circuits | LVP-4: Mean Well SDR-480-24 supplies PS-11 and PS-12 | LVP-4: Phoenix fused outputs F-22 through F-24; Shelly Pro RGBWW PM modules SH-22 through SH-24 | L-05 through L-07: lower bedroom/right-side and right-side service/bath tape-light areas |
| Blinds / shades | Dedicated shade/blind 120V control circuit from the assigned breaker panel | BC-1: shade controller power only; not part of tape-light 24V supply bank | BC-1: Somfy RS485/IP controller and RS485/motor terminal blocks | M-01 through M-11 shade/blind motor terminations |
| LAN / Homey control | UPS-backed 120V receptacle in the low-voltage rack for server, switch, and network equipment | Rack-mounted Homey self-hosted server, 48-port managed switch, and 48-port Cat6 patch panel | Ethernet LAN to Shelly Pro modules SH-01 through SH-24, 12 PoE touch-screen drops, 9 Wi-Fi AP drops including panic room AP, Somfy/BC-1 interface, Homey server, router/uplink, and spares | Control intent is LAN-local. Do not rely on cloud service for normal Shelly lighting control. |
| Smart smoke / CO | Standard 120V interconnected smoke/CO circuit by code; smart alarm units report location/status wirelessly | First Alert SC5 hardwired smart smoke/CO alarms or approved listed smart hardwired smoke/CO equal | 12-location allowance for plan review and costing; final count by code smoke/CO layout | Life-safety function remains in the listed alarm devices. Homey/app notification is monitoring only, not the life-safety controller. |
| Calculation Brief | High Voltage Scope | Low Voltage / Control Scope | Connected Control Load | Install Rule |
|---|---|---|---|---|
| Panel 1 + LVP-1 | Panel 1: Square D NQ30L4C 300A / 30-space panelboard. Feeds the upper-left/main area branch circuits and the LVP-1 lighting-control feed group. | LVP-1: 3 x Mean Well SDR-480-24 supplies PS-1 to PS-3; Phoenix fused outputs F-01 to F-05; Shelly Pro RGBWW PM modules SH-01 to SH-05; terminals U-01 through U-05. | 24V driver capacity: 1,440W. Approx. full-load input basis: 12A at 120V, or 6A service-equivalent at 240V. | Keep U-01 through U-05 in LVP-1 only. Do not move Panel 2/3/4 tape zones into this cabinet without revising the fuse, Shelly, and voltage-drop schedule. |
| Panel 2 + LVP-2 | Panel 2: Square D QO120L125G 125A / 20-space main-lug load center. Feeds the upper center/right branch circuits and the LVP-2 lighting-control feed group. | LVP-2: 5 x Mean Well SDR-480-24 supplies PS-4 to PS-8; Phoenix fused outputs F-06 to F-17; Shelly Pro RGBWW PM modules SH-06 to SH-17; terminals U-06 through U-17. | 24V driver capacity: 2,400W. Approx. full-load input basis: 20A at 120V, or 10A service-equivalent at 240V. | Split the five SDR-480 supplies across the Panel 2 lighting/control breakers shown on the panel schedule. Do not put more than two SDR-480 supplies on one 20A 120V branch unless a revised load calc is issued. |
| Panel 3 + LVP-3 | Panel 3: Square D QO120L125G 125A / 20-space main-lug load center. Feeds lower/main area branch circuits, the shared utility/motion lighting circuit, and the LVP-3 lighting-control feed group. | LVP-3: 2 x Mean Well SDR-480-24 supplies PS-9 to PS-10; Phoenix fused outputs F-18 to F-21; Shelly Pro RGBWW PM modules SH-18 to SH-21; terminals L-01 through L-04. | 24V driver capacity: 960W. Approx. full-load input basis: 8A at 120V, or 4A service-equivalent at 240V. Utility/motion lights remain 120V loads on the Panel 3 lighting circuit. | Keep lower/main tape zones L-01 through L-04 in LVP-3. Utility/motion fixtures can share the Panel 3 120V lighting circuit unless independent control is required. |
| Panel 4 + LVP-4 | Panel 4: Square D QO120L125G 125A / 20-space main-lug load center. Feeds lower/right and ADU-side branch circuits and the LVP-4 lighting-control feed group. | LVP-4: 2 x Mean Well SDR-480-24 supplies PS-11 to PS-12; Phoenix fused outputs F-22 to F-24; Shelly Pro RGBWW PM modules SH-22 to SH-24; terminals L-05 through L-07. | 24V driver capacity: 960W. Approx. full-load input basis: 8A at 120V, or 4A service-equivalent at 240V. | Keep lower/right and ADU-side tape zones L-05 through L-07 in LVP-4. Do not combine these outputs with LVP-3 unless the LVP schedule is revised. |
| BC-1 Blinds / Shades | Dedicated 1 x 15A 120V shade circuit from the assigned breaker panel. Keep shade power/control separate from the 24V tape-light driver banks. | BC-1: nVent Hoffman A24N206LP cabinet with A24N20MP back panel, Somfy RS485/IP shade controller, RS485 terminals, shade power/control terminals, and motor terminations M-01 through M-11. | 11 shade motors: 4.89A / 586.8W at 120V. Approx. service-equivalent basis: 2.45A at 240V. | BC-1 is the blinds/shades control cabinet only. Do not place tape-light 24V supplies, Shelly RGBWW modules, or tape-light fuses in BC-1. |
| LAN / Homey Server | Provide one UPS-backed 120V receptacle in the low-voltage rack for the server/network equipment. Keep rack power on the control/network circuit, not on a random general receptacle circuit. | Homey self-hosted server runs in Docker on the rack server. Shelly Pro RGBWW PM modules use wired Ethernet where practical; the Somfy/BC-1 interface, PoE touch screens, and Wi-Fi APs land on the same control LAN. | LAN device basis: 24 x Shelly modules, 12 x PoE touch screens, 9 x Wi-Fi AP drops, 1 x Homey server, 1 x Somfy/BC-1 interface, 1 x router/uplink, plus spares. Use a 48-port switch, not a 24-port switch. | Do not daisy-chain Ethernet between Shelly modules unless an Ethernet switch is installed at that cabinet. Preferred install is labeled Cat6 from patch panel/switch to each LAN device or to a local LVP DIN Ethernet switch if conduit count is limited. Cameras/NVR are excluded from this scope and will be handled in the AV/security package. |
| Smart Smoke / CO | Use normal 120V interconnected smoke/CO rough-in circuit wiring required by code. Smart reporting is wireless and does not need Cat6 to each alarm. | First Alert SC5 hardwired smart smoke/CO alarm basis, with room/location labels configured in the app. Homey may monitor notifications/integration where supported. | 12 x smart smoke/CO alarm allowance at 120V with battery backup. Final quantity and locations by code smoke/CO plan. | Do not power from Mean Well LED drivers. Do not control through Shelly. Homey/app status is supplemental monitoring only; listed alarms remain the life-safety system. |
| Network / Server Material | Purchasable Product Basis | Qty | Purpose / Costing Note |
|---|---|---|---|
| Homey self-hosted server | Protectli Vault Pro VP2420 or equal low-power Linux/Docker host, 8GB RAM minimum, 240GB SSD minimum, with optional 1RU rack mount | 1 | Runs Homey Self-Hosted Server in Docker with static LAN IP. Back up the Homey data folder. Wired Ethernet only. |
| Managed rack switch | Ubiquiti UniFi Switch 48 PoE / USW-48-POE, 48-port rack-mount managed switch | 1 minimum | Base control network consumes 45 ports before the Homey server, Somfy interface, router/uplink, or spares. Carry one 48-port PoE switch as the minimum and add a second switch/uplink expansion if all Shelly modules, screens, APs, server, Somfy, and spare ports are landed in this rack. Cameras/NVR are excluded from this scope. |
| Expansion switch allowance | Additional UniFi rack switch, 24-port minimum, PoE only if additional powered endpoints are added | 1 allowance | Provides practical spare ports after the 24 Shelly modules, 12 touch screens, 9 APs, server, Somfy interface, router/uplink, and rack service ports are connected. |
| Cat6 patch panel | Leviton 49255-H48 48-port QuickPort patch panel, 2RU, black, or equal Cat6-rated 48-port patch panel | 1 | Terminate all LVP/Shelly, BC-1, touch screen, AP, and network field Cat6 in the rack before patching to the switch. |
| Patch cords | Cat6 slim patch cords, rack length, color-coded by function | 48 | Patch panel to switch, server to switch, router/uplink to switch, Somfy/BC-1 to switch, and spare labeled jumpers. |
| Shelly LAN terminations | Cat6 home runs or rack/cabinet patching to Shelly Pro RGBWW PM Ethernet ports | 24 | One LAN connection for each Shelly module SH-01 through SH-24 when hardwired. Label both ends to match the panel schedule. |
| PoE touch-screen drops | Cat6 home run to each plan-shown wall touch-screen location, terminated at the rack patch panel and powered from the PoE switch | 12 | Count basis from wall-load DWFx schedules: 5 main-wall LAN4 PoE touch screens, 4 upper-wall Axion 8 in Android PoE touch screen objects, and 3 lower-wall Axion 8 in Android PoE touch screen objects. |
| PoE touch screens | Axion Android PoE Touch Screen, 8 in model A-TPIW80-P-V3 or current equal Android PoE wall panel | 12 | Wall-mounted control/dashboard screens for Homey/Shelly scenes, lighting, shades, and status. Provide single-gang back box/mounting support per screen product requirements. |
| Interior Wi-Fi AP drops | Cat6 home runs to ceiling AP locations, terminated at rack patch panel and powered from PoE switch | 6 | General interior Wi-Fi coverage. Final AP positions to be coordinated with ceiling layout, structure, and finish materials. |
| Panic room AP + spare data | Dedicated Cat6 home run for panic room AP plus one spare Cat6 data drop in the panic room | 1 AP + 1 spare | Do not rely on Wi-Fi from outside the panic room. Label AP drop AP-PR-01 and spare data drop DATA-PR-01 SPARE. Both terminate at the rack patch panel and remain UPS-backed. |
| Exterior Wi-Fi AP drops | Cat6 home runs to exterior-rated AP locations, terminated at rack patch panel and powered from PoE switch | 2 | Exterior/patio/garage approach coverage. Use outdoor-rated APs and weather-rated mounting methods. |
| Interior Wi-Fi APs | Ubiquiti UniFi U7 Pro or U7 Pro Max Wi-Fi 7 PoE access point | 7 | Six general interior APs plus one dedicated panic room AP. Panic room AP is mandatory because room construction may block RF from adjacent areas. |
| Exterior Wi-Fi APs | Ubiquiti UniFi U7 Outdoor or U7 Pro Outdoor Wi-Fi 7 PoE access point | 2 | Exterior AP basis for patio/yard/garage-side coverage. Cameras/NVR are not included here. |
| Network UPS | Rack UPS sized for server, switch, router, and controls | 1 | Keeps Homey, switch, router/uplink, and LAN-local lighting controls online during short power interruptions. Final VA/runtime by network rack load. |
| Homey Bridge / radio gateway | Homey Bridge only if Zigbee, Z-Wave, Bluetooth, 433 MHz, or IR devices are required | As required | The Shelly lighting control basis is wired LAN. Add bridge/radio hardware only for non-LAN devices that need those radios. |
| Smart smoke/CO alarms | First Alert SC5 Hardwire Smart Smoke and Carbon Monoxide Alarm, FSMCO600NVACCL1, or approved listed smart hardwired smoke/CO equal | 12 allowance | Smart/app location monitoring for smoke/CO. Unit is hardwired with battery backup and wireless smart connection; no Cat6 required at each alarm. Final count by smoke/CO code layout. |
| Budgetary Material Cost Summary | Qty | Unit Allowance | Extended | Included Scope |
|---|---|---|---|---|
| Interior LED tape | 10 | $1,966.95 | $19,669.50 | 100 ft spools, interior tape allowance |
| Exterior LED tape | 7 | $1,966.95 | $13,768.65 | 100 ft spools, exterior/wet-location tape allowance |
| Interior aluminum channel | 120 | $52.00 | $6,240.00 | 8 ft interior channel sticks |
| Exterior aluminum channel | 78 | $27.00 | $2,106.00 | 8 ft exterior channel sticks |
| Mean Well SDR-480-24 DIN supplies | 12 | $145.00 | $1,740.00 | 24V driver supplies |
| Shelly Pro RGBWW PM modules | 24 | $84.99 | $2,039.76 | DIN lighting controllers, SH-01 through SH-24 |
| Phoenix fused terminals | 30 | $18.00 | $540.00 | 24 scheduled outputs plus spare fused outputs |
| DIN rail, terminals, wire duct allowance | 1 | $1,500.00 | $1,500.00 | Miscellaneous cabinet interior build material |
| LVP / BC cabinet enclosure allowance | 1 | $6,425.00 | $6,425.00 | LVP-1 through LVP-4 plus BC-1 enclosure/back-panel allowance |
| Homey server | 1 | $650.00 | $650.00 | Protectli/Linux/Docker server allowance |
| 48-port PoE switch | 1 | $699.00 | $699.00 | Minimum rack PoE switch |
| 24-port expansion switch allowance | 1 | $399.00 | $399.00 | Additional network ports after control LAN build-out |
| 48-port Cat6 patch panel | 1 | $250.00 | $250.00 | Rack patch panel |
| Cat6 patch cords | 48 | $6.00 | $288.00 | Rack patching allowance |
| Axion PoE touch screens | 12 | $450.00 | $5,400.00 | Wall dashboard/control screen allowance |
| Interior Wi-Fi APs | 7 | $189.00 | $1,323.00 | Six general interior APs plus panic room AP |
| Exterior Wi-Fi APs | 2 | $199.00 | $398.00 | Exterior/patio Wi-Fi coverage |
| Rack UPS allowance | 1 | $600.00 | $600.00 | Network/control rack UPS |
| Homey Bridge allowance | 1 | $69.00 | $69.00 | Only if radio gateway is required |
| Smart hardwired smoke/CO alarms | 12 | $129.95 | $1,559.40 | First Alert SC5 hardwired smart smoke/CO allowance |
| Current scoped material total | $65,664.31 | Budgetary material only |
| Panel / Enclosure | Purchasable Cabinet / Size | Feed / Breakers | Installed Contents | Field Output |
|---|---|---|---|---|
| Panel 1 | Square D / Schneider NQ 400A, 30-space, 1-phase panelboard basis: NQ30L4C copper-bus interior, MH50WP box, NC50S surface cover, 300A main breaker kit/factory main | 300A feeder/main, 120/240V 1-phase, 30 spaces | Approx. 18 spaces used from current Panel 1 schedule, leaving 12 spare spaces for required AFCI/GFCI/SPD/field additions. | Branch circuits to assigned upper-left/main areas |
| Panel 2 | Square D / Schneider QO120L125G load center, main lug only, 125A, 20-space / 20-circuit, 120/240V 1-phase, NEMA 1, with QO breakers | 125A feeder/main-lug subpanel, 20 spaces | Approx. 14 labeled circuit positions shown from the current Panel 2 schedule including three 2-pole loads and blinds, leaving 6 visible spare spaces. | Branch circuits to assigned upper/right areas |
| Panel 3 | Square D / Schneider QO120L125G load center, main lug only, 125A, 20-space / 20-circuit, 120/240V 1-phase, NEMA 1, with QO breakers | 125A feeder/main-lug subpanel, 20 spaces | Approx. 16 spaces shown from the current Panel 3 schedule including utility 20A and two 2-pole loads, leaving 4 spare spaces. | Branch circuits to assigned lower/main areas |
| Panel 4 | Square D / Schneider QO120L125G load center, main lug only, 125A, 20-space / 20-circuit, 120/240V 1-phase, NEMA 1, with QO breakers | 125A feeder/main-lug subpanel, 20 spaces | Approx. 10 spaces shown from the current Panel 4 schedule including two 2-pole loads, leaving 10 spare spaces. | Branch circuits to assigned lower/ADU areas |
| LVP-1 | nVent Hoffman A42N3013 Type 1, 42 in H x 30 in W x 13.25 in D, with A42P30 back panel | 120V feed from Panel 1 lighting/control circuit group | 3 x Mean Well SDR-480-24 DIN supplies PS-1 to PS-3, Phoenix fused outputs F-01 to F-05, Shelly Pro RGBWW PM modules SH-01 to SH-05, 24V distribution and output terminals | U-01 through U-05, Panel 1 area tape zones |
| LVP-2 | nVent Hoffman A42N3613 Type 1, 42 in H x 36 in W x 13.25 in D, with A42P36 back panel | 120V feed from Panel 2 lighting/control circuit group | 5 x Mean Well SDR-480-24 DIN supplies PS-4 to PS-8, Phoenix fused outputs F-06 to F-17, Shelly Pro RGBWW PM modules SH-06 to SH-17, 24V distribution and output terminals | U-06 through U-17, Panel 2 area tape zones |
| LVP-3 | nVent Hoffman A42N3013 Type 1, 42 in H x 30 in W x 13.25 in D, with A42P30 back panel | 120V feed from Panel 3 lighting/control circuit group | 2 x Mean Well SDR-480-24 DIN supplies PS-9 to PS-10, Phoenix fused outputs F-18 to F-21, Shelly Pro RGBWW PM modules SH-18 to SH-21, 24V distribution and output terminals | L-01 through L-04, Panel 3 area tape zones |
| LVP-4 | nVent Hoffman A42N3013 Type 1, 42 in H x 30 in W x 13.25 in D, with A42P30 back panel | 120V feed from Panel 4 lighting/control circuit group | 2 x Mean Well SDR-480-24 DIN supplies PS-11 to PS-12, Phoenix fused outputs F-22 to F-24, Shelly Pro RGBWW PM modules SH-22 to SH-24, 24V distribution and output terminals | L-05 through L-07, Panel 4 area tape zones |
| BC-1 | nVent Hoffman A24N206LP Type 1, 24 in H x 20 in W x 6.62 in D, with A24N20MP back panel | 1 x 15A 120V shade circuit | Somfy RS485/IP shade controller, RS485 terminal blocks, shade power/control terminations | 11 shade/blind motors |
| Control Cabinet | DIN Rail / Mounting Layout | Space Basis | Required Interior Build |
|---|---|---|---|
| LVP-1 | NS35 DIN rails on A42P30 back panel. Row 1: 120V line/load terminals and Mean Well PS-1 through PS-3. Row 2: 24V distribution, Phoenix F-01 through F-05, Shelly SH-01 through SH-05, U-01 through U-05 terminals. Wire duct on both sides and between rows. | Three SDR-480 supplies plus five fuses and five Shelly modules fit in a 30 in wide Hoffman cabinet with landing and duct space. | Panel 1 area only. Do not put Panel 2/3/4 tape zones in this cabinet. |
| LVP-2 | NS35 DIN rails on A42P36 back panel. Row 1: 120V line/load terminals and Mean Well PS-4 through PS-8. Row 2/3: 24V distribution, Phoenix F-06 through F-17, Shelly SH-06 through SH-17, U-06 through U-17 terminals. Wire duct on both sides and between rows. | Five SDR-480 supplies plus twelve fuses and twelve Shelly modules need the wider 36 in Hoffman cabinet for labeling and heat/landing space. | Panel 2 area only. Do not put Panel 1/3/4 tape zones in this cabinet. |
| LVP-3 | NS35 DIN rails on A42P30 back panel. Row 1: 120V line/load terminals and Mean Well PS-9 through PS-10. Row 2: 24V distribution, Phoenix F-18 through F-21, Shelly SH-18 through SH-21, L-01 through L-04 terminals. Wire duct on both sides and between rows. | Two SDR-480 supplies plus four fuses and four Shelly modules fit in a 30 in wide Hoffman cabinet with spare space for terminals. | Panel 3 area only. Includes lower/main zones L-01 through L-04. |
| LVP-4 | NS35 DIN rails on A42P30 back panel. Row 1: 120V line/load terminals and Mean Well PS-11 through PS-12. Row 2: 24V distribution, Phoenix F-22 through F-24, Shelly SH-22 through SH-24, L-05 through L-07 terminals. Wire duct on both sides and between rows. | Two SDR-480 supplies plus three fuses and three Shelly modules fit in a 30 in wide Hoffman cabinet with spare space for terminals. | Panel 4 area only. Includes lower/right and ADU-side zones L-05 through L-07. |
| BC-1 | One or two NS35 DIN rails on A24N20MP back panel. Row 1: 120V shade circuit terminals and shade power/control module. Row 2: RS485 terminal blocks and motor terminals M-01 through M-11. | 24 x 20 cabinet is sized for the shade controller, RS485 terminals, motor labels, and service slack. | 1 x 15A feed. Keep shade controls separate from tape-light 24V distribution. |
| Panel Feed | Purpose | Shelly Zones | 24V Bank Capacity | 120V Breaker |
|---|---|---|---|---|
| UDB / Upper lighting | Build from 8 x Mean Well SDR-480-24 DIN power supplies, 3 x Hoffman A24N206LP enclosures, Phoenix Contact 3036505 fused terminals, and Shelly Pro RGBWW PM modules | 17 | 3,840W @ 24V | 2 x 20A, 120V |
| LDB / Lower lighting | Build from 4 x Mean Well SDR-480-24 DIN power supplies, 2 x Hoffman A24N206LP enclosures, Phoenix Contact 3036505 fused terminals, and Shelly Pro RGBWW PM modules | 7 | 1,920W @ 24V | 1 x 20A, 120V |
| BC-1 / Blinds-Shades | Dedicated shade control panel/circuit for 11 Somfy Sonesse RS485 shade motors and Somfy SDN/animeo IP RS485 control interface | 11 motors | 586.8W @ 120V | 1 x 15A, 120V |
| Main meter | Main wall-load DWFx object: Main_Electrical_Panel_with_Meter_20855 / City Meter | 1 | N/A | Service equipment by electrician/utility service design. |
| Main Power Panel | Main wall-load DWFx object: Leviton load center / EcoFlow Ocean Pro Smart Panel | 1 | N/A | DWFx type mark is EcoFlow Ocean Pro Smart Panel. Verify final equipment package and listing. |
| Main Power Panel 2 | Main wall-load DWFx object: Leviton load center / 100A Service | 1 | N/A | DWFx type mark is 100A Service. Coordinate with final panel schedule and service/load calculation. |
| 1-120 utility | Shared 120V utility/motion fixtures: mechanical, garage mechanical, pantry/storage, ADU 120V, and three utility lights | 7 fixtures | N/A | Use existing/shared 120V lighting circuit where code/load allows; use separate Shelly relay only for independent app/control switching. |